Jungle Property
-
Grant Multi Pass Kitchen and Boiler House Models 50/70 70/90 90/140 140/160 160/200 User Installation and Servicing Instructions
Read more: Grant Multi Pass Kitchen and Boiler House Models 50/70 70/90 90/140 140/160 160/200 User Installation and Servicing InstructionsGrant Multi Pass Kitchen and Boiler House Models 50 70 70 90 90 140 140 160 160 200 User Installation and Servicing Instructions
-
Kenwood CK 280 Instructions for Use
Read more: Kenwood CK 280 Instructions for UseKenwood CK 280 Instructions for Use
-
Potterton Controls Customer Guide for the EP2000 EP2002 EP3002
Read more: Potterton Controls Customer Guide for the EP2000 EP2002 EP3002Potterton Controls Customer Guide for the EP2000 EP2002 EP3002
-
Stovax Stockton Clean-burn stove Installation and Operating Instructions
Read more: Stovax Stockton Clean-burn stove Installation and Operating InstructionsStovax Stockton Clean-burn stove Installation and Operating Instructions
-
My windows will not close and the landlord wants to seal them shut is this right?
Read more: My windows will not close and the landlord wants to seal them shut is this right?A window is a structural component, and a window is clearly intended to open and close, just as the front door is intended to open and close. As such this is a landlord repairing obligation under s.11 of the Landlord & Tenant Act 1985 and the landlord needs to be reminded of his legal obligation to repair the window. A sealed window could prevent escape in the event of a fire – ask the landlord to confirm the sealed window has been/will be covered in the fire risk assessment and ask to see a copy of the fire risk assessment.…
-
Why does the landlord’s address need to be on the tenancy agreement?
Read more: Why does the landlord’s address need to be on the tenancy agreement?The landlord’s address is included on the tenancy agreement to comply with Section 47 and 48 of the Landlord and Tenant Act 1987. Section 47 of the Act requires that the tenant must be provided with the name and address of the landlord on any demand for rent or other sums due under the terms of the tenancy or long lease. Section 48 of Landlord and Tenant Act 1987 requires landlords to provide an address, which must be in England or Wales, at which notices may be served on them by their tenants or leaseholders. The failure to provide such…
-
Beko ESG50 Cooker Owner Manual
Read more: Beko ESG50 Cooker Owner ManualBeko ESG50 Cooker Owner Manual
-
What is a visual check of the electrical installation?
Read more: What is a visual check of the electrical installation?Unlike periodic inspection and testing of the electrical installation, visual checks are not a legal requirement. When a change of tenancy occurs, the landlord or their representative should always carry out a visual check to confirm that a property is safe to re-let. This check should include confirming that there are no broken or missing switches or sockets, no accessible live parts, no signs of burning on electrical equipment and that any installed RCDs operate when the integral test button is pressed. Things to look out for include: Broken accessories (such as sockets and light switches). Signs of scorching around…
-
Does my solid fuel burning stove need a ventilation grate?
Read more: Does my solid fuel burning stove need a ventilation grate?The ventilation requirements for combustion installations and the additional provisions for appliances burning solid fuel are covered by Approved Document J. These requirements are not specific to rental properties. We recommend you arrange for a stove installer such as a HETAS (HETAS Ltd operates the Heating Equipment Testing and Approval Scheme) registered installer to seek expert advice on this. Further Reading Approved Document J | Part J – Combustion appliances and fuel storage systems | Planning Portal Still not answered your question? We love questions so fire it at us using the contact details here Please rate this article so we…
